R5V08.jpg

R5 Pressure Control Valves R5S Series

     Denison R5 series pressure control valves deliver maximum adjustable pressures up to 210/280/350 bar and flow capacities ranging from 90 l/min to 600 l/min. R5 Valves are capable of extremely precise pressure settings and feature responsive flutter free control. Search Lifco Hydraulics R5 stock below:


Search Lifco Hydraulics Inventory:

logo-denison.jpg

parkerkeepitreala.png


Select Product Type: Units   
Unit#(Click item for more)DescriptionStockPrice(USD)
R5S0851316A1R5S0851316A12 In Stock$774.15
016-87218-0R5S06 511 16 A1Out Of StockPlease Contact Us
026-65039-0R5S06 533 16 A1Out Of StockPlease Contact Us
026-57765-0R5S10 433 16 A1Out Of StockPlease Contact Us
026-52013-0R5S10C443 16 A1Out Of StockPlease Contact Us

Specifications:

R5 2 Port R5 3 Port
Port Sizes: 3/4', 1', 1 1/4' 3/4', 1', 1 1/4', 1 1/2' (R5V, R5U)
Direction of Flow: A->B (R5V, R5S) B->A (R5R) A->B
Ambient Temperature Range: -20 to +60 C -20 to +60 C
Fluid Temperature Range: -18 to +80 C -18 to +80 C
Max Flow: R5*06 (3/4'): 90 l/min
R5*08 (1'): 300 l/min
R5*10 (1 1/4'): 600 l/min
R5*06 (3/4'): 90 l/min
R5*08 (1'): 300 l/min
R5*10 (1 1/4'): 600 l/min
R5V/R5U12 (1 1/2'): 600 l/min
Nominal Flow: R5*06 (3/4'): 60 l/min
R5*08 (1'): 200 l/min
R5*10 (1 1/4'): 450 l/min
Depends on pump delivery
Need Assistance?   sales@lifcohydraulics.com
1-800-895-4326

R5S0851316A1 R5S0851316A1

Buy Direct Link:Buy Direct
Price(USD):$774.15
Stock:2 In Stock




Application: R5 Pressure Control Valves


     Do you need a SAE 4 bolt mounted, pilot operated pressure control valve to fasten directly onto your hydraulic pump or into your hydraulic piping? Parker’s R5 series valve will meet or exceed your expectations. Available for use as R5V relief, R4U unloading, R4S sequence or R4R reducing functions, they are rated up to 5,000 PSI maximum and can handle flows up to 160 GPM (this is more than 150 horsepower). As a relief valve it will safely limit the maximum pressure a hydraulic circuit can reach. The unloading valve is used to sense the pressure in another part of a hydraulic circuit and vent a pump’s flow to tank when it is not needed – this is a great energy saver when used in conjunction with another pump (high/low system) or with an accumulator. Sequence valves are used to control the operational order that functions within a hydraulic system must execute in. The R5R reducing valve, limits the pressure to any one hydraulic circuit, ensuring the force exerted by its actuators do not exceed any specific level. This reducing valve is also available with an integral reverse flow check valve. Each type of R5 valve has three sizes; 3/4” (SAE -12, Code 61 & 16 GPM), 1” (SAE -16, Code 61, & 53 GPM) and 1-1/4” (SAE -20, Code 61, & 120 GPM), to suit your flow rate requirements. There is even a 1-1/2” size (SAE -24, Code 62, & 120 GPM); only available in the R5V relief and the R5U unloading models. Any of these R5 valves come with one of three adjustable pressure levels (2,000 PSI, 3,000 PSI or 5,000 PSI), to make sure that they cannot be inadvertently adjusted too high. The pressure adjustments can be made with any of three devices; a hand knob & jam nut, an acorn nut & lead seal or a hand knob & key lock. Parker has designed these valves with removable pilot sections; in this way a solenoid valve (Parker’s VV01) or an electronic proportional pilot (Parker’s 4VP01) can be sandwiched between this pilot and the main valve body. The VV01 is used to electrically vent the R4 valve pilot and the 4VP01 is used to control the actual pressure level of the R4 valve remotely. The body style exists in either 2 port (for inline mounting) or in 3 port (for Teeing off of a line).